Jump to main content or area navigation.

Contact Us

Pacific Southwest, Region 9: Superfund

Serving Arizona, California, Hawaii, Nevada, the Pacific Islands, and Tribal Nations

Fairchild Semiconductor Corp. (Mountain View Plant)

EPA #: CAD095989778

State: California(CA)

County: Santa Clara

City: Mountain View

Congressional District: 14

Other Names: Part of Middlefield-Ellis-Whisman (MEW) Study Area

Bulletin Board

Aug 2010: EPA announces its selection of the vapor intrusion remedy for the MEW Superfund Study Area in EPA’s Record of Decision Amendment for the Vapor Intrusion Pathway (Click Here). EPA thanks the community for comments received on the Proposed Plan & for participating in the decision making process.

Links

Description and History

NPL Listing History

NPL Status: Final

Proposed Date: 10/15/84

Final Date: 02/11/91

Deleted Date:

The 56-acre former Fairchild Semiconductor Corp. - Mountain View facilities manufactured semiconductors and is located in Mountain View, California. The Fairchild Semiconductor Corp - Mountain View site is one of three Superfund or National Priorities List (NPL) sites that are being cleaned up simultaneously. The other two Superfund sites are the Intel - Mountain View site and the Raytheon site. All three sites are located in the Middlefield-Ellis-Whisman (MEW) Study Area and are being addressed collectively as the MEW SIte. Site investigations at several of these facilities during 1981 and 1982 revealed extensive soil and groundwater contamination, primarily volatile organic compounds (VOCs).

Fourteen potential sources of contamination have been identified at the former Fairchild facilities, including underground and aboveground storage tanks for chemical products and wastes, pH neutralization systems, and industrial wastewater treatment systems.

Top of page

Contaminants and Risks

Contaminated Media
  • Groundwater
  • Air
  • Soil and Sludges

The primary contaminants of concern are trichloroethene (TCE) and other volatile organic compounds (VOCs). The soil has been cleaned up to meet the soil cleanup standards

Top of page

Who is Involved

This site is being addressed through Federal and potentially responsible parties' actions.

Top of page

Investigation and Cleanup Activities

The contamination addressed in the MEW Record of Decision is both facility-specific and regional. Each individual MEW Company is responsible for investigation, cleanup, and source control for soil and groundwater contamination at their individual facility-specific properties south of U.S. Highway 101. Contaminated groundwater that has bypassed the source control areas and has mixed together with other contaminated groundwater from other source areas is considered part of the regional groundwater contamination plume, or the “regional plume.”



    The MEW Regional Groundwater Remediation Program systems south and north of U.S. Highway 101 are designed to contain and clean up contaminated groundwater where it has mixed together with other contaminated groundwater and where the source of contamination has not been identified. The Navy and NASA both operate groundwater extraction and treatment systems to contain and clean up contaminated groundwater at their areas of responsibility on Moffett Field, in addition to the regional system operating North of 101 on Moffett Field.

    It is important to note that groundwater currently is not used for drinking water or other potable uses. Groundwater in the area is, however, a potential future source of drinking water and therefore groundwater cleanup standards have been established.

Initial Actions

Initial cleanup actions included removing tanks from the site, removing and treating soil, sealing wells serving as potential conduits, and controlling groundwater movement by installing three slurry walls and 21 groundwater extraction wells.

Remedy Selected

In June 1989, EPA issued a Record of Decision selecting the soil and groundwater cleanup remedy for the MEW Site. The soil remedy includes: excavation, with treatment by aeration; and soil vapor extraction with treatment by vapor-phase granular activated carbon. The groundwater remedy includes: slurry walls (barriers beneath the surface) to contain contaminants; and extraction and treatment systems to contain and clean up groundwater contamination using granular activated carbon and/or air-stripping systems.
Because the groundwater contamination at the MEW Site migrates northward and has mixed with contamination from sources at the NAS Moffett Field Superfund site, the groundwater remedy selected in the MEW Record of Decision also applies to the commingled regional groundwater contamination area on former NAS Moffett Field (the West-Side Aquifers), but not the entire former NAS Moffett Field facility.

515/545 Whisman Road and 313 Fairchild Drive (Former Buildings 1-4)

In 1986, Fairdhild installed a 40-foot deep slurry wall was installed in 1986 along the boundaries of these properties to limit migration of chemicals, and was keyed into the A/B aquitard. Groundwater extraction was initiated in the mid-1980s to control and clean up sources in the groundwater. The system was expanded and currently includes 12 source control extraction wells both inside and outside the slurry wall. The MEW Regional Program operates three wells outside the slurry wall. Treatment systems 1 and 3 have treated over an estimated 900 million gallons of groundwater and removed over 34,000 pounds of VOCs from the groundwater through December 2006.

401 National Avenue (Former Building 9)

In 1986, Fairchild installed a slurry wall along the boundaries of this property and that was keyed into the A/B aquitard at a depth of approximately 40 feet. Groundwater extraction began at this property in 1982 from well 65A. Since then, the groundwater system has been expanded to include four source control extraction wells within the slurry wall enclosure. Extracted groundwater from the five A Aquifer wells is treated at System 1. Three other source control extraction wells (GSF-1A, GSF-1B1, and GSF-1B2) have also been installed north of this facility and are the joint responsibility of Vishay/SUMCO and Fairchild/Schlumberger.

369 and 441 North Whisman Road (Former Buildings 13, 19, 23)

In 1986, Fairchild installed an approximately 40-foot-deep slurry wall along the boundaries of the 369 North Whisman Road property, keyed into the A/B aquitard. Groundwater extraction began in 1982 at this property, and was expanded to include seven A Aquifer source control extraction wells within the slurry wall enclosure; two A Aquifer source control extraction wells downgradient of the slurry wall to the north; three source control extraction wells in the B1 Aquifer; and two source control extraction wells in the B2 Aquifer. Groundwater extracted from these wells is piped to System 19, located at 369 North Whisman Road, for treatment. System 19 has treated over 800,000 gallons of groundwater and removed over 10,000 pounds of VOCs from the groundwater through December 2006.

644 National Avenue (Former Building 18)

One source control extraction well (RW-25A) currently operates in the A Aquifer northwest of the building. Groundwater from this extraction well is treated at System 1. System 1 also treats water from two basement-dewatering sumps at 644 National Avenue.

464 Ellis Street (Former Building 20)

No potential sources were found at this property. Raytheon installed and currently operates two source control extraction wells in the A and B1 Aquifers, respectively. These wells capture contaminants immediately downgradient of the Raytheon slurry wall. Groundwater from the two wells is conveyed to the Raytheon system at 350 Ellis Street for treatment.

EPA First Five-Year Review

EPA's 2004 Five-Year Review for the MEW Study Area determined that for the groundwater remedy to remain protective in the long-term, the following actions need to be taken: long-term protectiveness should continue to be verified by monitoring the extent of groundwater contamination along the estimated groundwater contamination plume boundaries. This evaluation should be accomplished through routine annual groundwater sampling events. Current data indicate that the remedy is functioning as required to meet the remedial action objectives; however, EPA recommends optimization of both the regional and facility-specific systems to enhance plume capture, evaluation of applicable technologies to potentially expedite contaminant mass removal and cleanup time, and evaluation of the potential need for institutional controls.

Current Actions

The MEW Companies, Navy and NASA have prepared a work plan to evaluate other alternate groundwater cleanup technologies to address the MEW Site-wide groundwater contamination.

Site Studies

EPA Evaluates Vapor Intrusion Pathway
The existing soil and groundwater remedy at the MEW Site does not address risks from long-term exposure through the vapor intrusion pathway. Since the issuance of EPA’s 1989 Record of Decision, new information has been developed regarding the toxicity of TCE and potential vapor intrusion into buildings overlying shallow groundwater contamination. In 2003, as part of EPA’s Five-Year Review of the MEW Study Area, EPA began evaluating whether VOCs in shallow groundwater are potentially migrating upward through the soils and cracks in the floors or through plumbing conduits and other preferential pathways, and impacting indoor air.

Based on indoor air sampling of both commercial and residential buildings in the area conducted in 2003 to 2007, EPA has confirmed the presence of the subsurface vapor intrusion pathway into a number of structures overlying the shallow groundwater TCE plume. None of the samples taken to date indicate any immediate or short-term health threat to building occupants from this pathway. EPA’s main concern is whether the chemicals from the Site measured in indoor air pose an unacceptable risk of chronic health effects due to long-term exposure (25 years or more). It is EPA’s policy not to set cleanup levels or take action to reduce levels that are less than ambient background levels.

Some of the sampled buildings indicated indoor air contaminant concentrations that were elevated above background levels and above EPA Region 9’s TCE interim action level in indoor air for long-term exposure. In each of these buildings, the MEW Companies and NASA have taken voluntary interim measures (e.g., sealing cracks/conduits, upgrading/modifying ventilation systems, installing air purifying systems) to reduce the indoor air contaminant concentrations. In addition, many new buildings in the MEW Study Area have taken measures to help prevent or mitigate the vapor intrusion pathway. Although EPA has not yet determined what the long-term mitigation and monitoring strategy should be for all buildings overlying shallow groundwater contamination, the results of these interim measures have generally reduced the indoor air levels thus far and are protective of residents and workers.

EPA continues to evaluate this pathway and potential mitigation measures for impacted buildings overlying the shallow TCE plume. EPA is currently conducting and planning the following actions:

  • Continue evaluation of buildings overlying the shallow TCE plume to identify potential pathways into buildings, and implement mitigation measures to reduce elevated levels of TCE in indoor air, as appropriate;
  • Develop remedial action objectives to address the vapor intrusion pathway;
  • Assess various alternatives and propose a remedy to address the vapor intrusion pathway.
  • Amend the MEW Record of Decision to select a remedy that addresses potential long-term exposure of TCE and other VOCs at unacceptable levels through the vapor intrusion pathway.

In 1985, EPA issued an Administrative Order on Consent to the parties potentially responsible for site contamination. As a result of this Order, the potentially responsible parties conducted an investigation to determine the nature and extent of the site contamination. In 1990, EPA issued an Administrative Order requiring the clean up of the sites and responsibility for the long-term operation of the regional groundwater extraction system.

Top of page

Cleanup Results to Date

Under EPA’s direction and oversight, the MEW Companies, including Fairchild Semiconductor Corp. and Schlumberger Technology Corp., implemented the soil and groundwater cleanup programs that have included soil excavation and treatment, installation of four slurry walls, soil vapor extraction and treatment systems, and groundwater extraction and treatment systems. The soil cleanup by soil vapor extraction and excavation and aeration has been completed at all the former MEW facilities, including the former Fairchild facilities.
Groundwater cleanup will continue to operate for many decades in order to meet the TCE groundwater cleanup standard of 5 parts per billion. The MEW Site groundwater remedy has removed over 76,000 pounds of contaminants, and has reduced contaminant concentrations throughout the multiple aquifer zones. The groundwater is not being used as a potable water supply, and there are no direct exposure pathways to the contaminated groundwater while groundwater cleanup continues.

Top of page

Potentially Responsible Parties


Potentially responsible parties (PRPs) refers to companies that are potentially responsible for generating, transporting, or disposing of the hazardous waste found at the site.


Under EPA's direction and regulatory oversight, Schlumberger Technology Corporation is responsible for investigating and cleaning up the soil and groundwater at the Fairchild-Mountain View Superfund Site. In addition, the following individual companies are responsible for investigating and cleaning up the groundwater at the MEW Site. These companies are collectively referred to as the MEW Companies:

  • Fairchild Semiconductor Corporation
  • Intel Corporation
  • Raytheon Company
  • Schlumberger Technology Corp. (Schlumberger)
  • Renesas Electronics America Inc. (formerly NEC Electronics America, Inc.)
  • SMI Holding LLC (SMI)
  • Vishay General Semiconductor (Vishay)
  • SUMCO Phoenix Corporation (SUMCO)
  • National Semiconductor Corporation
  • Tracor X-Ray
  • Union Carbide

National Semiconductor Corporation, Tracor X-Ray, and Union Carbide are not involved with the active investigation and cleanup of the MEW Site.

Top of page

Documents and Reports


Hide details for Administrative RecordsAdministrative Records
05/22/89Administrative Record, MEW Study Area
09/01/90Administrative Record AR 9151
Remedial
Update 3
Update 4
Update 5
Update 6
Hide details for Fact SheetsFact Sheets
05/01/86New Contamination Found in Mountain View's Deep Aquifer
11/01/88EPA Announces Proposed Plan to Clean Up MEW Superfund Sites
07/01/89EPA Announces Clean-Up Plan for MEW Study Area
11/01/92Middlefield-Ellis-Whisman (MEW) Superfund Study Area
05/01/96Cleanup Activities Underway Within MEW Study Area
11/01/99Construction Activities Completed - Redevelopment Continues
01/01/03EPA Evaluates Indoor Air Pathway
03/01/03EPA Hosts Community Advisory Group Informational Meeting (English and Spanish Versions)
04/01/03Air Sampling Begins (English and Spanish Versions)
05/01/03First Community Advisory Group Meeting, May 14, 2003 (in English and Spanish)
04/01/04EPA Conducting Five Year Review of Clean Up Remedy
02/01/07EPA Informational Open House (English and Spanish Versions)
02/01/07Middlefield-Ellis-Whisman (MEW) Superfund Study Area
07/09/09Updated - EPA Announces Proposed Plan for the Vapor Intrusion Pathway (English and Spanish)
07/23/09EPA Proposed Plan Public Meeting Presentation slides handout (color and black & white versions)
07/23/09Updated - Extends Public Comment Period to Sept 8, 2009 - EPA Announces Proposed Plan for the Vapor Intrusion Pathway (English and Spanish)
08/20/09Updated - Extends Public Comment Period to Oct 8, 2009 - EPA Announces Proposed Plan for the Vapor Intrusion Pathway (English and Spanish)
09/18/09Updated: Extends Public Comment through Nov 7, 2009 - EPA's Proposed Plan for the Vapor Intrusion Pathway
Hide details for Legal DocumentsLegal Documents
11/29/90Administrative Order for Remedial Design and Remedial Action
09/16/11Amendment 91-4A to MEW Administrative Order for Vapor Intrusion Remedial Design and Remedial Action
Hide details for MapsMaps
12/08/11Vapor Intrusion Study Area - MEW Area - South of U.S. Highway 101 - updated December 2011
Hide details for Records of DecisionRecords of Decision
06/09/89Record of Decision for MEW Study Area
09/01/90Explanation of Significant Differences
04/16/96Explanation of Significant Differences
08/16/10Record of Decision Amendment for the Vapor Intrusion Pathway
Hide details for Technical DocumentsTechnical Documents
09/30/04Final First Five Year Review Report
04/08/092008 Annual Progress Report for 455, 485/487 and 501/505 East Middlefield Road
04/15/092008 Annual Progress Report for 401/405 National Avenue site
04/15/092008 Annual Progress Report for 501 Ellis Street
06/15/092008 Annual Progress Report for Fairchild
06/15/092008 Annual Progress Report for MEW Regional Study Area
06/29/09Final Supplemental Feasibility Study for the Vapor Intrusion Pathway
06/29/09Final Supplemental Remedial Investigation for the Vapor Intrusion Pathway
07/09/09Proposed Plan for the Vapor Intrusion Pathway (updated to fix Table 3 title to Future Buildings)
08/20/09EPA Potential Changes to Proposed Vapor Intrusion remedy - Aug 20, 2009
08/20/09Updated to reflect extended public comment period - Proposed Plan for the Vapor Intrusion Pathway
09/18/09Cover page of Proposed Plan updated to reflect public comment period extended to Nov 7, 2009 - Proposed Plan for Vapor Intrusion Pathway
09/30/09Final Second Five-Year Review for the MEW Superfund Study Area
11/07/09Public Comments Received on EPA's Proposed Plan for the Vapor Intrusion Pathway during public comment period (July 10 - Nov 7, 2009)
06/15/102009 Annual Progress Report for former Fairchild facilities - Bldgs 1-4, 9, 18, 19, 20
06/15/102009 Annual Progress Report for MEW Regional Groundwater Remediation Program
04/15/112010 Annual Progress Report for Vishay/SUMCO/Schlumberger 405/425 National Avenue
06/15/112010 Annual Progress Report for former Fairchild facilities - Bldgs 1-4, 9, 18, 19, 20
06/15/112010 Annual Progress Report for MEW Regional Groundwater Remediation Program
04/13/122011 Annual Progress Report for former Fairchild facilities - Bldgs 1-4, 9, 18, 19, 20
04/13/122011 Annual Progress Report for MEW Regional Groundwater Remediation Program (excluding Appendices B, C and F)
04/13/122011 Annual Progress Report for Vishay/SUMCO/Schlumberger 405/425 National Avenue
02/22/13Indoor Air Sampling Report – Former Fairchild properties – Google Quad – 369-399 N Whisman Rd and 464 Ellis St

Top of page

Community Involvement

Public Meetings: A community advisory group, the MEW Community Advisory Board, meets to learn about and discuss MEW Superfund Study Area investigation and cleanup issues.

EPA has awarded a Technical Assistance Grant (TAG) to the Pacific Studies Center. The TAG provides money for activities that help the community understand technical information at the MEW Site. Please contact Lenny Siegel, TAG Administrator, at 650-961-8918 or LSiegel@cpeo.org for more information.

Top of page

Public Information Repositories

The public information repositories for the site are at the following locations:

Mountain View Public Library,
585 Franklin Street,
Mountain View, CA 94041
Hours:
Monday-Thursday 10 am to 9 pm
Friday and Saturday 10 am to 6 pm
Sunday 1 pm to 5 pm
650-903-6887

The most complete collection of documents is the official EPA site file, maintained at the following location:

Superfund Records Center

Mail Stop SFD-7C

95 Hawthorne Street, Room 403

San Francisco, CA 94105

(415) 820-4700

Enter main lobby of 75 Hawthorne street, go to 4th floor of South Wing Annex.

Additional Links

Top of page

Contacts

EPA Site Manager
Alana Lee
Penny Reddy
415-972-3141
415-972-3108
Lee.Alana@epamail.epa.gov
Reddy.Penny@epamail.epa.gov
US EPA Region 9
Mail Code SFD
75 Hawthorne Street
San Francisco, CA 94105
EPA Community Involvement Coordinator
Alejandro Diaz
415-972-3242
1-800-231-3075
Diaz.Alejandro@epamail.epa.gov
US EPA Region 9
Mail Code SFD
75 Hawthorne Street
San Francisco, CA 94105
EPA Public Information Center
415-947-8701
r9.info@epa.gov
State Contact
PRP Contact
Community Contact
Lenny Siegel
650-961-8918
LSiegel@cpeo.org
Center for Public Environmental Oversight,
a Project of the Pacific Studies Center,
278A Hope Street
Mountain View, CA 94041
Other Contacts
After Hours (Emergency Response)
US EPA
(800) 424-8802

Top of page