Title:SPENT PICKLE LIQUOR CORROSIVITY
RCRA Online Number:11346
Date:05/02/1988
To:Boulden
From:Barnes
Organization of Recipient:Ladish Co, Inc.
Description: Spent pickle liquor generated by a steel fabricator is not K062 since the facility is not in SIC codes 331 or 332. Nonlisted spent pickle liquor is corrosive if it corrodes 1020 steel at a rate of >0.25 inches/year. Nonlisted sludge from a pickling tank is D002 if pH of the sludge is < 2. The 264.314 liquids in landfills ban does not apply to nonhazardous waste disposal facilities.
Regulatory Citation(s) : 258.28, 261.22(a)(2), 261.32, 264.314, 265.314 EXIT disclaimer
Statutory Citation(s):NA Read US Code 42, Chapter 82 EXIT disclaimer
Topic(s):Characteristic Wastes; Corrosive Wastes; Disposal; Industrial Wastes; K-wastes; Land Disposal Units; Landfills; Municipal Solid Waste; Nonhazardous Waste; Tanks; TSDFs