Title:FLASH POINT TESTING OF A WASTE FIBROUS FILTER MATERIAL
RCRA Online Number:14669
Date:05/19/2003
To:Springer
From:Lopez
Organization of Recipient:PSC Environmental
Description: Only liquid wastes are evaluated for ignitability using the flash point test in 261.21(a)(1). Non-liquid wastes, such as fibrous filter material, are assessed for ignitability using the narrative criteria found in 261.21(a)(2). No specific federal test has been developed for determining the ignitability of non-liquid wastes. State implementing agencies may have tests or guidance for determining non-liquid waste ignitability.
Regulatory Citation(s) : 261.21, 261.21(a)(1), 261.21(a)(2) EXIT disclaimer
Statutory Citation(s):NA Read US Code 42, Chapter 82 EXIT disclaimer
Topic(s):Characteristic Wastes; Identification of Hazardous Waste; Test Methods