Full Document:
Title:GUIDANCE ON RCRA SUBPART J SECONDARY CONTAINMENT REQUIREMENTS AT AUTOMOBILE SPRAY PAINTING OPERATIONS
RCRA Online Number:14632
Date:11/18/2002
To:RCRA Senior Policy Advisors, Regions I-X
From:Springer
Organization of Recipient:NA
Description: The point of generation is when the paint-solvent mixture exits the spray gun. Piping from the point of generation to a storage tank is ancillary equipment and needs secondary containment. A building may fulfill the secondary containment requirements for indoor tanks and ancillary equipment if it is in accordance with 265.193(b) and (c). Compliance with the secondary containment provisions is site-specific. An owner may apply for a technology-based variance from the secondary containment requirements per 265.193(g). Automobile manufacturing plants that manage purge solvent may receive a variance if certain criteria are met.
Regulatory Citation(s) : 265.193, 265.193(b), 265.193(c), 265.193(g), 265.193(h) EXIT disclaimer
Statutory Citation(s):NA Read US Code 42, Chapter 82 EXIT disclaimer
Topic(s):Tanks; Variances
Approximate Number of Hardcopy Pages:5
EPA Publication Number:NA
RPPC Number (if applicable): NA