Title:TETRACHLOROETHYLENE CONTAMINATED WITH POLYCHLORINATED BIPHENYLS (PCBS)
RCRA Online Number:11470
Date:09/22/1989
To:Wassersug, Region 3
From:Lowrance
Organization of Recipient:EPA
Description: Cleaning PCBs from a transformer with solvent containing 10% or more tetrachloroethylene (PCE) before use results in F002 listed waste. Applicable TSCA PCB regulations do not supersede the RCRA regulations. If TSCA and RCRA rules conflict, the more stringent regulations take precedence. Using solvent as dielectric is not "solvent use" triggering F001-F005 listings.
Regulatory Citation(s) : 261.8, 261.31 EXIT disclaimer
Statutory Citation(s):NA Read US Code 42, Chapter 82 EXIT disclaimer
Topic(s):F-wastes; Hazardous Waste; Industrial Wastes; Solvents