Title:CLASSIFICATION OF F003 WASTES
RCRA Online Number:11707
Date:11/04/1992
To:Noles
From:Lowrance
Organization of Recipient:Four Seasons Industrial Services, Inc.
Description: Xylene and acetone used to remove paint is F003, even if the waste is not ignitable. The 261.3(a)(2)(iii) mixture rule exemption does not apply to nonignitable F003 that has not yet been mixed with solid waste, and does not apply to a mixture of soil and F003 that does not exhibit a characteristic (SEE ALSO: 66 FR 27266; 5/16/01). Land disposal restrictions (LDR) treatment requirements still apply to F003 waste that has been rendered nonignitable and/or nonhazardous under 261.3(a)(2)(iii). If F003 is spilled into soil, the soil must be managed as listed waste until the state or Region determines that it no longer contains hazardous waste.
Regulatory Citation(s) : 261.3(a)(2), 261.31, 268.40 EXIT disclaimer
Statutory Citation(s):NA Read US Code 42, Chapter 82 EXIT disclaimer
Topic(s):Characteristic Wastes; Disposal; F-wastes; Hazardous Waste; Industrial Wastes; Land Disposal Restrictions; Nonhazardous Waste; Solvents; Treatment
Approximate Number of Hardcopy Pages:3
EPA Publication Number:NA
RPPC Number (if applicable): 9444.1992(05)
Official OSW Policy:Yes

 

 