Skip common site navigation and headers
US EPA
RCRA Online
Begin Hierarchical Links You are here: EPA Home >> Wastes >> Information Sources >> RCRA Online >> Document Record Detail End Hierarchical Links
Welcome What's New Topics Full Text Search Advanced Search Help

Document Record Detail



Full Document:
Title:IGNITABILITY CHARACTERISTIC, DEFINITION OF UNDER STANDARD TEMPERATURE AND PRESSURE
RCRA Online Number:11369
Date:09/09/1988
To:Muno, HQ
From:Lowrance
Organization of Recipient:EPA
Description: A waste need not be evaluated for a flash point if it is not a liquid at standard temperature (20C/68F) and pressure (1 atmosphere). Polystyrene production distillation still bottom tar is not a liquid at standard temperature and pressure and, for purposes of ignitability characteristic, need be evaluated only against 261.21(a)(2) criterion.
Regulatory Citation(s) : 261.21 EXIT disclaimer
Statutory Citation(s):NA Read US Code 42, Chapter 82 EXIT disclaimer
Topic(s):Characteristic Wastes; Hazardous Waste; Test Methods
Approximate Number of Hardcopy Pages:1
EPA Publication Number:NA
RPPC Number (if applicable): 9443.1988(08)
Official OSW Policy:No

 

 